@ -44,6 +44,24 @@ RTC
|
||||||
|
|
||||||
The onboard Real Time Clock (RTC) is used to track the uptime a periodically start querying all electricity meter for their measurement value.
|
The onboard Real Time Clock (RTC) is used to track the uptime a periodically start querying all electricity meter for their measurement value.
|
||||||
The time interval between the periodic queries is hard coded in `main.c`.
|
The time interval between the periodic queries is hard coded in `main.c`.
|
||||||
|
By connecting a (coin cell) battery to VBAT the RTC keeps running, even if the board is not powered anymore.
|
||||||
|
|
||||||
|
DDM100TC
|
||||||
|
--------
|
||||||
|
|
||||||
|
This 3-phase 4-wire electricity meter provides an S0 interface.
|
||||||
|
|
||||||
|
On my model this would output 1600 impulse/kWh, thus each impulse corresponds to a power consumption of 0.625 Wh).
|
||||||
|
To record these impulses a timer input capture is used.
|
||||||
|
The number of impulses determines the energy used.
|
||||||
|
It is stored in a backup register, keeping the value in memory even when the board is powered down as long as a (coin cell) battery is connected to VBAT.
|
||||||
|
The interval between impulses allow to calculate the current power consumption.
|
||||||
|
The time has a resolution of 0.91 ms (leading to a power calculation error of <1%).
|
||||||
|
|
||||||
|
Connections DDM100TC <-> board:
|
||||||
|
|
||||||
|
- S0+, pin 8; +3.3V or +5V
|
||||||
|
- S0-, pin 7; TIM4_CH1, PB6 (use pull-down resistor)
|
||||||
|
|
||||||
ESP8266
|