Note: when connecting multiple meters one the same UART bus only keep one of the pull-up resistors (across all meters) on the TX pin (on the opto-coupler output), else the low level is not low enough for the micro-controller to correctly decode the signal.
|
||||
|
||||
SDM120
|
||||
------
|
||||
|
||||
This 1-phase 2-wire electricity meter provides an RS-485 interface using the ModBus RTU protocol.
|
||||
For the 3-phase 4-wire power distribution installation I used 3 meters, one per phase.
|
||||
|
||||
They can be connected to the same RS-485 bus once individual addresses have been set.
|
||||
The used meter IDs (aka. slave address) are hard coded in `main.c`
|
||||
A UART to RS-485 converter is used to be able to communicate with the meters.
|
||||
|
||||
The SDM120 ModBus protocol document provide by Eastron specify the commands and registers, but the timing (important) is specified in the SDM630 ModBus protocol document.
|
||||
|
||||
Connections 3xSDM120 <-> board:
|
||||
|
||||
- VCC; +5V
|
||||
- GND; ground
|
||||
- DI; PB10, USART3_TX
|
||||
- DE; PB1 (shared with RE since one is active low while the other is active high)
|
||||
- RE; PB1 (shared with DE since one is active low while the other is active high)
|
||||
- RO; PB11, USART3_RX
|
||||
|
||||